Product Descriptions

Product Descriptions


Reusable sensors for detecting organic solutions

(LK16-T2-2000HD)

- Product Explanation

  • 5th-generation sensors
  • Reusable sensors for detecting special high molecular organic solvents 
  • Detect organic solutions, such as oil and coal tar
  • Very fast response speed of within 40 seconds
  • Detect hydrogen peroxide, ammonia and MDI
ClassificationSpecification
ItemSensors for detecting reuse of oil/organic solutions
ModelLK16-T2-2000HD
MeasurementWidth: 28mm / Thickness: 500㎛
Detected LiquidOil/organic solutions including diesel/gasoline/toluene
Detected TimeDifferent according to the concentration of solutions and the temperature of the installation locations
Detected Liquid AmountOver 5 ㎖
Temperature/
Humidity
-10~45 ℃ / 5~85%
Power SupplyDC 5V
Chemical Resistance
Reuse
Explosion-proof LevelEx ib ⅡB T6

Multi-leak alarm module sensors

(LK18-T3-3001 / LK18-T3-3002)

- Product Explanation

  • 6th-generation sensors
  • Reusable sensors for detecting composite leaks of harmful chemical solutions or organic/oil substances
  • Confirm districts (locations) of parts of organic and oil leaks through the existence of communication function
  • Simplify installation structure, fast construction and reduce work costs
ClassificationSpecification
ItemSensors for detecting reuse of conductive, chemical solutions/ Organic solutions, Oil
ModelLK18-T3-3001
LK18-T3-3002
MeasurementWidth : 38mm / Thickness : Over 130mm
Detected LiquidConductive solutions, chemical / organic, oil
Detected TimeWithin 5min
Detected Liquid AmountOver 5 ㎖
Temperature/
Humidity
-20~80 ℃ / 5~85%
Power SupplyDC 5V
Chemical Resistance
Reuse
Explosion-proof LevelEx ib ⅡB T5

Reusable sensors for detecting chemical solutions

(LK14-T2-2001AC)

- Product Explanation

  • 4th-generation sensors
  • Reusable sensors for detecting leaks of acid and alkali liquid
  • Fast response speed and explosion-proof
  • Use for non-explosion-proof areas
  • High durability, corrosion-resistance and weather-resistance
Classification
Specification
Item
Reusable sensors for detecting chemical solutions
Model
LK14-T2-2001AC
Measurement
Width: 28mm / Thickness: 130㎛
Detected Liquid
Chemical solutions such as hydrochloric acid, nitric acid, hydrofluoric acid and sulfuric acid
Detected Time
Within 5 min (Different according to the set value of alarm modules)
Detected Liquid Amount
Over 5 ㎖
Temperature/
Humidity
-10~55 ℃ / 5~85%
Power supply
DC 5V
Chemical Resistance
Reuse
Explosion-proof Level
Ex ib ⅡB T6

Sensors for detecting chemical solutions

(LK14-T2-1001AC)

- Product Explanation

  • The world’s first film-type sensors for detecting chemical solutions
  • Detect acid and alkali solutions
  • No reaction to moisture (snow, rain, fog) and good for indoor and outdoor installation
Classification
Specification
Item
Sensors for detecting chemical solutions
Model
LK14-T2-1001AC
Measurement
Width: 28mm / Thickness: 370㎛
Detected Liquid
50% Caustic soda
Detected Time
Within 5 min (Different according to the set value of alarm modules)
Detected Liquid Amount
Over 5 ㎖
Temperature/
Humidity
-10~55 ℃ / 5~85%
Power supply
DC 5V
Chemical Resistance
Reuse
○ (Different according to the concentration of solutions)
Explosion-proof Level
Ex ib ⅡB T6

Sensors for detecting distance to water leaks

(LK08-T1)

- Product Explanation

  • The world’s first film-type sensors for detecting distance to water leaks
  • Fast response speed and highly competitive price
  • Can detect exact locations (distance) of water leaks
Classification
Specification
Item
Sensors for for detecting distance to water leaks
Model
LK08-T1
Measurement
Width : 28mm / Thickness : 370㎛
Detected Liquid
Conductive solutions
Detected Time
Within 1~30 sec. (Different according to the set value of alarm modules)
Detected Liquid Amount
Over 5 ㎖
Temperature/
Humidity
-10~55 ℃ / 5~85%
Power supply
DC 5V
Chemical Resistance
Reuse
○ (Different according to the concentration of solutions)
Explosion-proof Level
Ex ib ⅡB T6

Sensors for detecting water leaks

(LK08-T1-ST)

- Product Explanation

  • The world’s first film-type sensors for detecting water leaks
  • Fast response speed and highly competitive price
  • Simple installation and low maintenance and repair costs
Classification
VSpecification
Item
Sensors for detecting water leak
Model
LK08-T1-ST
Measurement
Width : 28mm / Thickness : 370㎛
Detected Liquid
Conductive solutions
Detected Time
Within 1~30 sec. (Different according to the set value of alarm modules)
Detected Liquid Amount
Over 5 ㎖
Temperature/
Humidity
-10~55 ℃ / 5~85%
Power supply
DC 5V
Chemical Resistance
Reuse
○ (Different according to the concentration of solutions)
Explosion-proof Level
Ex ib ⅡB T6

Magnetic resonance (induction)-type sensors for detecting liquid leaks 

(LK19-T7-1000)

- Product Explanation

  • 8th-generation sensors
  • The world’s first magnetic resonance (induction)-type film sensors
  • High-speed detection of conductive liquid, such as acid and alkali liquid and water
  • Non-contacting and semipermanent reusable sensors with excellent durability and drug-resistance
Classification
Specification
Item
Magnetic resonance (induction)-type sensors
Model
LK19-T7-1000
Measurement
Width : 48mm / Thickness : 0.9mm
Detected Liquid
Chemical solutions such as hydrochloric acid, nitric acid, hydrofluoric acid and sulfuric acid
Detected Time
Within 5min (Different according to each solution)
Detected Liquid Amount
Over 3Hole at the least
Temperature/
Humidity
-10~55℃ / 5~85℃
Power supply
DC 5V
Chemical Resistance
Reuse
Explosion-proof Level
Ex ib ⅡB T6

Magnetic resonance (induction)-type area sensors for detecting liquid leaks

(TK19-T7-1001)

- Product Explanation

  • 8th-generation magnetic resonance (induction)-type area sensors
  • High-speed detection of conductive liquid, such as acid and alkali liquid and water
  • Non-contacting and semipermanent reusable sensors with excellent durability and drug-resistance
  • Can be manufactured according to various conditions and can be installed in narrow space
Classification
Specification
Item

Model
TK19-T7-1001
Measurement

Detected Liquid

Detected Time

Detected Liquid Amount

Temperature/
Humidity

Power supply

Chemical Resistance

Reuse

Explosion-proof Level